DATASHEET
LA-ON-SH-V.09
REV 01 · 2026-07 · EN
ONLINE UPS · SERIE LA-ON-SH-V.09Stable power
for sensitive equipment
Double conversion, Schuko outlets and complete UPS status monitoring.
Online double conversion
TECHNOLOGY
3 models
LA-ON-1K · 2K · 3K SH-V.09
Tower
FORMAT
IDEAL FOR
Servers
NAS & storage
Network equipment
CCTV
QUICK DECISIONThe essentials, at a glance
Key figures for the range
POWER
1 - 3 kVA
POWER FACTOR
0,9
OUTPUTS
Schuko
COMMUNICATION
USB + RS-232
Optional SNMP · AS400 · ModBus
TECHNICAL ADVANTAGESKey features
● True double-conversion online UPS
● Microprocessor control for optimized reliability
● Output power factor 0.9
● Input power factor correction
● Wide input voltage range (110V - 300V)
● Optional ECO mode operation for energy saving
● 50/60Hz output frequency conversion mode
● Generator compatible
3-year electronics warranty
2-year battery warranty
Free pickup & return service
Only applicable in the Iberian Peninsula
www.laparaups.com
contacto@laparaups.com
REV 01 · 2026-07 · EN
LA-ON-SH-V.09
01 / 02
Technical specifications
SERIE LA-ON-SH-V.09 | ONLINE UPS
MODEL
LA-ON-1K-SH-V.09
LA-ON-2K-SH-V.09
LA-ON-3K-SH-V.09
| CAPACITY* | 1000 VA / 900 W | 2000 VA / 1800 W | 3000 VA / 2700 W |
| INPUT |
| Voltage range (Low line voltage transfer) | 90VAC/80VAC/70VAC/60VAC ± 5% or 180VAC/160VAC/140VAC/120VAC ± 5% (ambient temperature < 35ºC) (based on % load: 100% - 80% / 80% - 70% / 70% - 60% / 60% - 0) |
| Voltage range (Low line voltage recovery) | 95VAC/85VAC/75VAC/65VAC or 175VAC/155VAC/135VAC/125VAC ± 5% (ambient temperature < 35ºC) (based on % load: 100% - 80% / 80% - 70% / 70% - 60% / 60% - 0) |
| Voltage range (High voltage transfer) | 145 VAC ± 5% or 300 VAC ± 5% |
| Voltage range (High voltage recovery) | 140 VAC ± 5% or 290 VAC ± 5% |
| Frequency range | 40Hz ~ 70 Hz |
| Phase | Single-phase with ground |
| Power factor | ≧ 0.99 at nominal voltage (input voltage) |
| OUTPUT |
| Output voltage | 110/115/120/127VAC or 208/220/230/240VAC (default: 230 VAC) |
| AC voltage regulation | ±1% (Battery mode) |
| Frequency range | 47 ~ 53 Hz or 57 ~ 63 Hz (synchronized range) |
| Frequency range (Battery mode) | 50 Hz ± 0.5 Hz or 60 Hz ± 0.5 Hz |
| Overload | Ambient temperature < 35ºC; 105%~110%: the UPS shuts down after 10 minutes in battery mode or switches to bypass mode when mains power is normal; 110%~130%: the UPS shuts down after 1 minute in battery mode or switches to bypass mode when mains power is normal; >130%: the UPS shuts down after 3 seconds in battery mode or switches to bypass mode when mains power is normal |
| Crest factor | 3:1 |
| Harmonic distortion | ≦ 3% THD (linear load); ≦ 6% THD (non-linear load) |
| Transfer time (AC mode to Battery) | Zero |
| Transfer time (Inverter to Bypass) | 4 ms (typical) |
| Waveform (Battery mode) | Pure sine wave |
| EFFICIENCY |
| AC mode | 88% | 89% | 90% |
| Battery mode | 83% | 87% | 88% |
| BATTERY |
| Standard model (Battery type) | 12 V / 9 AH | 12 V / 9 AH | 12 V / 9 AH |
| Standard model (Number) | 2 | 4 | 6 |
| Standard model (Recharge time) | 4 hours to charge to 90% of capacity (typical) |
| Standard model (Charge current) | 1.0 A (max.) |
| Standard model (Charging voltage) | 27.4 VDC ± 1% | 54.7 VDC ± 1% | 82.1 VDC ± 1% |
| CONNECTIONS |
| Power outlets | 3 x Schuko | 3 x Schuko | 4 x Schuko + Terminal Block |
| Communication ports | 1xUSB + 1xRS232 + 1x intelligent port |
| PHYSICAL CHARACTERISTICS |
| Standard model (Dimensions, D x W x H) | 282 X 145 X 220 (mm) | 397 X 145 X 220 (mm) | 421 X 190 X 318 (mm) |
| Standard model (Net weight, kg) | 9,3 | 16,7 | 26,5 |
| ENVIRONMENTAL CONDITIONS |
| Relative humidity | 20-90% RH @ 0-40°C (non-condensing) |
| Noise level | < 50dBA at 1 meter |
| MANAGEMENT |
| Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC |
| Optional SNMP | Power management via an SNMP manager and web browser |
* Specifications subject to change without notice. Please refer to the applicable service conditions.
www.laparaups.com
contacto@laparaups.com
LA-ON-SH-V.09