DATASHEET
LA-ON33-V.10
REV 01 · 2026-08 · EN
THREE-PHASE ONLINE UPS · SERIE LA-ON33-V.10
Maximum protection
for three-phase loads
High efficiency, touch display and parallel operation for critical installations.
SERIE  LA-ON33-V.10
Three-phase online
TECHNOLOGY
3 models
LA-ON33-10K · 20K · 30K
Tower
FORMAT
IDEAL FOR
Data centers
Industry
Hospitals
Critical infrastructure
QUICK DECISION
The essentials, at a glance
Key figures for the range
POWER
10 - 30 kVA
INPUT/OUTPUT
3F + N
EFFICIENCY
Up to 98.5%
PARALLEL
Up to 4 units
TECHNICAL ADVANTAGES
Key features
●  True double-conversion online UPS
●  DSP technology that guarantees high performance
●  Output power factor 1
●  Silicon carbide diodes to improve system efficiency
●  Dual input voltage system
●  Adjustable charging current
●  Supports up to 4 units in parallel with common battery
●  5" colour touch LCD display
2-year electronics warranty
1-year battery warranty
Free pickup & return service
Only applicable in the Iberian Peninsula
www.laparaups.com
contacto@laparaups.com
REV 01 · 2026-08 · EN
LA-ON33-V.10
01 / 02
Technical specifications
SERIE LA-ON33-V.10  |  THREE-PHASE ONLINE UPS
MODEL
LA-ON33-10K-V.10
LA-ON33-20K-V.10
LA-ON33-30K-V.10
Capacity*10.000 VA / 10.000 W20.000 VA / 20.000 W30.000 VA / 30.000 W
Parallel compatibilityUp to 4 units in parallel
INPUT
Nominal voltage3 x 400 VAC (3F+N)
Voltage range190-520 VAC (3 phases) @ 50% load; 305-478 VAC (3 phases) @ 100% load
Frequency range46Hz ~ 54Hz or 56Hz ~ 64Hz
Power factor≥ 0.99 at 100% load
OUTPUT
Output voltage3 x 360*/380/400/415 VAC (3F+N)
AC voltage regulation (Battery mode)±1%
Frequency range (Synchronized range)46Hz ~ 54Hz or 56Hz ~ 64Hz
Frequency range (Battery mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Harmonic distortion≤ 2% THD linear loads; ≤ 5% THD non-linear loads
Overload (AC mode)100%~110%: 60 min; 110%~125%: 10 min; >150%: 1 sec
Overload (Battery mode)100%~110%: 60 min; 110%~125%: 10 min; >150%: 1 sec
Crest current value3:1 max
Transfer time (Mains ↔ Battery)0 ms
Transfer time (Inverter ↔ Bypass)0 ms
Crest current ratio3:1 (max)
Waveform (Battery mode)Pure sine wave
EFFICIENCY
AC mode96.0%
ECO mode98.5%
Battery mode95.0%
BATTERY
Battery type12V / 9AH12V / 9AH12V / 7AH
Number(10 + 10) units(16 + 16) units(16 + 16) units x 2 strings
Recharge time9 hours to recharge to 90% capacity
Charging current (max)1A ~ 12A (adjustable)
Charging voltage±136.5 VDC ± 10%±218 VDC ± 10%±218 VDC ± 10%
INDICATORS
5" colour touch LCD displayUPS status, load level, battery level, input/output voltage, discharge time and faults
ALARM
Battery modeSounding every 4 seconds
Low batterySounding every second
OverloadSounds twice every second
FaultContinuous sound
PHYSICAL CHARACTERISTICS
Standard model626 x 250 x 750 (mm)626 x 250 x 750 (mm)815 x 300 x 1000 (mm)
Net weight (kg)124 Kg139 Kg225 Kg
ENVIRONMENTAL CONDITIONS
Operating temperature0 ~ 40°C (battery life is reduced at temp. > 25°C)
Relative humidity<95% non-condensing
Noise level< 55dBA at 1 meter< 58dBA at 1 meter< 65dBA at 1 meter
MANAGEMENT
Smart RS-232 or USBSupports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC
Optional SNMPPower management via an SNMP manager and web browser
* Specifications subject to change without notice. Please refer to the applicable service conditions.
www.laparaups.com
contacto@laparaups.com
LA-ON33-V.10