MAINTENANCE BYPASS FOR UPS LA-PDU-SM-T-SCHK

Watch the product videoYouTube

Maintenance bypass switch for UPS with Schuko outlets designed for installations with UPS up to 3000 VA, allowing manual load transfer to mains without cutting power to connected equipment. Its Master/Slave design adds an energy-saving function and makes it a practical solution for safe maintenance and electrical distribution in a compact desktop / floor format.

Categories: ,
✓Maintenance bypass with Schuko outlets
✓Allows manual load transfer to mains without interrupting supply
✓Provides continuous power to connected equipment during UPS maintenance or replacement
✓Master/Slave design for energy saving
✓Automatic disconnection of Slave outlets when Master outlet consumption is below 20W (±5W)
✓Easy operation via rotary switch
✓Plug & Play connectivity for input and output
✓Suitable for UPS up to 3000 VA
✓Compact desktop / floor format
19" rack maintenance bypass LA-PDU-SM-T-SCHK

Parameter LA-PDU-SM-T-SCHK
Product Maintenance Bypass Switch
Model LA-PDU-SM-T-SCHK
Application External distribution unit for UPS
ELECTRICAL CHARACTERISTICS
Rated current 16A
Rated voltage 208 / 220 / 230 / 240 VAC
Energy saving Yes. If Master outlet consumption is below 20W (±5W), Slave outlets are disconnected
LED INDICATORS
Power LED Green light
Master/Slave Function LED Green light
CONNECTIONS
Main Power 1 x IEC C20 (16A)
Input from UPS 1 x IEC C20 (16A)
Output to UPS 1 x IEC C19 (16A)
Master Output 1 x SCHUKO (16A)
Slave Output 3 x SCHUKO (16A)
PHYSICAL DATA
Dimensions 200 x 180 x 50 mm
Color Black
Weight 1.5 kg
Format Compact desktop
WORKING ENVIRONMENT
Temperature 0°C – 40°C
Humidity 20% - 90% RH (non-condensing)
CONTENT AND LOGISTICS
Package content Maintenance bypass LA-PDU-SM-T-SCHK, input cable

GENERAL
Product
Maintenance Bypass Switch
Model
LA-PDU-SM-T-SCHK
Model code
19” MBS
Application
External distribution unit for UPS
ELECTRICAL CHARACTERISTICS
Rated current
16A
Rated voltage
208 / 220 / 230 / 240 VAC
Energy saving
Yes. If Master outlet consumption is below 20W (±5W), Slave outlets are disconnected
LED INDICATORS
Power LED
Green light
Master/Slave Function LED
Green light
CONNECTIONS
Main Power
1 x IEC C20 (16A)
Input from UPS
1 x IEC C20 (16A)
Output to UPS
1 x IEC C19 (16A)
Master Output
1 x SCHUKO (16A)
Slave Output
3 x SCHUKO (16A)
PHYSICAL DATA
Dimensions
200 x 180 x 50 mm
Color
Black
Weight
1.5 kg
Format
Compact desktop
WORKING ENVIRONMENT
Temperature
0°C – 40°C
Humidity
20% - 90% RH (non-condensing)
CONTENT AND LOGISTICS
Package content
Maintenance bypass LA-PDU-SM-T-SCHK, input cable

Documentation

PDF
Datasheet
PDF
EU Declaration of Conformity
PDF
RoHS declaration
PDF
Certificate of origin

Documents automatically generated in the page language.