LA-ITR-LCD-V.09 LINE-INTERACTIVE UPS
The high-performance LA-ITR-LCD Interactive UPS is recommended for professional use, offering high efficiency thanks to its microprocessor control technology and smart card slot for management. This makes it one of the best options for sensitive electronic devices. The ITR UPS provides high protection for mid-range servers, workstations, NAS, active voice and data network equipment, etc.
![]()
✓Line-Interactive UPS
✓Pure sine wave
✓LCD Display
✓Output Power Factor 0.9
✓Off-mode charging
✓Cold start function
✓Microprocessor control guarantees reliability
✓Auto restart while AC is recovering
✓Built-in AVR to ensure voltage stability
✓Emergency Power Off (EPO) Function
✓ECO Mode for Energy Saving
✓Programmable Output Sockets
✓Multiple Communication Ports: USB, RS-232, SNMP (optional)
✓Hot-Swappable Batteries
✓Tower/Rack (RT) Design
ITR-RT Series Interactive Sine Wave UPS
| Model | LA-ITR-1100-LCD-V.09 | LA-ITR-1500-LCD-V.09 | LA-ITR-2000-LCD-V.09 | LA-ITR-3000-LCD-V.09 |
|---|---|---|---|---|
| Capacity | 1100 VA / 950 W | 1500 VA / 1300 W | 2000 VA / 1800 W | 3000 VA / 2700 W |
| INPUT | ||||
| Voltage | 110/120 VAC or 220/230/240 VAC | |||
| Voltage range | 81-145 VAC / 162-290 VAC | |||
| Frequency range | 60/50 Hz (auto sensed) | |||
| OUTPUT | ||||
| AC Voltage Regulation | 208/220/230/240 VAC | |||
| Voltage Regulation (Battery Mode) | +/-1% (Before alarm) | |||
| Frequency Range (Battery Mode) | 60 Hz or 50 Hz +/-1 Hz | |||
| Crest Factor | 3:01 | |||
| Harmonic Distortion | 5% max at 100% linear load, 10% max at 100% non-linear load (Before alarm) | |||
| Transfer Time | Typical 2-6 ms, 10 ms max. | |||
| Waveform (Battery Mode) | Pure Sine Wave | |||
| BATTERY | ||||
| Type & Quantity | 12V / 9AH x2 | 12V / 7AH x4 | 12V / 9AH x4 | 12V / 9AH x6 |
| Runtime (50% Load) | 10 min | 13 min | 13 min | 12 min |
| Recharge Time | 4 hours to 90% capacity | |||
| INDICATORS | ||||
| Digital LCD Panel | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault and Low Battery | |||
| PROTECTION | ||||
| Full protection | Overload, discharge and overcharge protection | |||
| ALARM | ||||
| Battery mode | Sounding every 10 seconds | |||
| Low battery | Sounding every second | |||
| Overload | Sounding every 0.5 seconds | |||
| Fault | Continuously sounding | |||
| INTERFACE | ||||
| Output Connections | 8x IEC | 7x IEC | ||
| Communication Ports | 1x USB + RS232 + 1xRJ11 | |||
| PHYSICAL DATA | ||||
| Dimensions DxWxH (mm) | 380 x 438 x 88 | 480 x 438 x 88 | 600 x 438 x 88 | 600 x 438 x 88 |
| Net Weight (Kg) | 13.20 | 19.00 | 21.00 | 29.10 |
| OPERATING ENVIRONMENT | ||||
| Humidity | 0-90% RH @ 0-40°C (non-condensing) | |||
| Noise Level | Less than 45dB | |||
| MANAGEMENT SOFTWARE | ||||
| Supported OS | Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC | |||
| SNMP | Optional. Management via SNMP manager and web browser. | |||
MODELS
Capacity
1100-LCD
1100 VA / 950 W
1500-LCD
1500 VA / 1300 W
2000-LCD
2000 VA / 1800 W
3000-LCD
3000 VA / 2700 W
INPUT
Voltage
110/120 VAC or 220/230/240 VAC
Voltage range
81-145 VAC / 162-290 VAC
Frequency range
60/50 Hz (auto sensed)
OUTPUT
AC Voltage Regulation
208/220/230/240 VAC
Voltage Regulation (Battery Mode)
+/-1% (Before alarm)
Frequency Range (Battery Mode)
60 Hz or 50 Hz +/-1 Hz
Crest Factor
3:01
Harmonic Distortion
5% max at 100% linear load, 10% max at 100% non-linear load (Before alarm)
Transfer time
Typical 2-6 ms, 10 ms max.
Waveform (Battery mode)
Pure sine wave
BATTERY
Type and quantity
1100-LCD
12V / 9AH x2
1500-LCD
12V / 7AH x4
2000-LCD
12V / 9AH x4
3000-LCD
12V / 9AH x6
Runtime (50% Load)
1100-LCD
10 min
1500-LCD
13 min
2000-LCD
13 min
3000-LCD
12 min
Recharge time
4 hours to 90% capacity
INDICATORS
Digital LCD Panel
AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery
PROTECTION
Full protection
Overload, discharge and overcharge protection
ALARM
Battery mode
Every 10 seconds
Low battery
Every second
Overload
Every 0.5 seconds
Fault
Continuous
INTERFACE
Output connections
1100 / 1500 / 2000
8x IEC
3000
7x IEC
Communication ports
1x USB + RS232 + 1xRJ11
PHYSICAL DATA
Dimensions D×W×H (mm)
1100-LCD
380 x 438 x 88
1500-LCD
480 x 438 x 88
2000-LCD
600 x 438 x 88
3000-LCD
600 x 438 x 88
Net weight (kg)
1100-LCD
13,20
1500-LCD
19,00
2000-LCD
21,00
3000-LCD
29,10
OPERATING ENVIRONMENT
Humidity
0-90% RH @ 0-40°C (non-condensing)
Noise level
Less than 45dB
MANAGEMENT SOFTWARE
Supported OS
Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix, and MAC
SNMP
Optional. Management via SNMP manager and web browser.
Documentation