ONLINE UPS LA-ON-RACK-6-10K-V.10
Online UPS LA-ON-RACK-6-10K designed for high-power critical rack applications, with true double conversion, DSP technology, output power factor 1 and high efficiency, also featuring advanced management, compatibility with external battery banks, optional N+X parallel redundancy, and multiple communication interfaces for continuous, stable, professional electrical protection.
![]()
✓True double-conversion online UPS
✓Output power factor 1
✓Ready to connect external battery banks
✓Wide input voltage range (110–300 VAC)
✓DSP technology ensures high performance
✓High efficiency up to 94%
✓Active input power factor correction 0.99
✓Frequency converter mode 50 Hz/60 Hz
✓Emergency Power Off (EPO) function
✓Generator compatible
✓Adjustable number of batteries
✓Programmable ECO mode operation for energy saving
✓Overvoltage cut-off protection and MOV surge immunity
✓Multiple communication ports: SNMP (optional) + USB + RS-232
✓Optional N + X parallel redundancy
✓Optional OVCD protection
Description
High-capacity UPS with a high level of protection, capable of keeping your company running during possible power supply failures.
LA-ON-RACK-V.10 Series Online UPS
| Model | LA-ON-6K-RACK-V.10 | LA-ON-10K-RACK-V.10 |
|---|---|---|
| Capacity* | 6000VA / 6000W | 10000VA / 10000W |
| INPUT | ||
| Line loss | 110–300 VAC @ (0–60%) load / 140–300 VAC @ (60–80%) load / 176–300 VAC @ (80–100%) load | |
| Line recovery - low | Low line-loss voltage + 10 V | |
| Line recovery - high | High line-loss voltage - 10 V | |
| Frequency range | Programmable 46 Hz–54 Hz @ 50 Hz / 56 Hz–64 Hz @ 60 Hz | |
| Phase | Single-phase with earth (phase + neutral) | |
| Power factor | ≧ 0.99 at nominal voltage and 100% load | |
| THDi | <4% at 100% load, <6% at 50% load | |
| OUTPUT | ||
| Low-voltage transfer | Programmable 208/220/230/240 VAC | |
| AC voltage regulation (Battery mode) | ± 1% | |
| Frequency range (Synchronized range) | Programmable 46 Hz–54 Hz @ 50 Hz / 56 Hz–64 Hz @ 60 Hz | |
| Frequency range (Battery mode) | Programmable 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |
| Crest factor | 3:1 | |
| Harmonic distortion | ≦ 1% @ 100% linear loads; ≦ 4% @ 100% non-linear loads | |
| Mains ↔ Battery | 0 ms | |
| Inverter ↔ Bypass | 0 ms | |
| Inverter ↔ ECO | <10 ms | |
| Waveform (Battery mode) | Pure sine wave | |
| EFFICIENCY | ||
| AC mode | >94% | |
| ECO mode | >94% | |
| BATTERY | ||
| Battery type | 12 V / 7 AH | 12 V / 9 AH |
| Quantity | 20 | 20 |
| Typical recharge time | 7 hours to recharge 90% capacity | 9 hours to recharge 90% capacity |
| Charging current | 1 A ± 10% (max.) | |
| Charging voltage | (Number of batteries*13.65 V) ± 1% | |
| INDICATORS | ||
| LCD display | UPS status, load level, battery level, input/output voltage, discharge time, and fault conditions. | |
| ALARMS | ||
| Battery mode | Beep every 4 seconds | |
| Low battery | Beep every second | |
| Overload | Beep twice every second | |
| Fault | Continuous beep | |
| PHYSICAL DATA | ||
| UPS dimensions D x W x H (mm) | 600 x 438 x 88 (2U) | |
| Battery bank dimensions D x W x H (mm) | 600 x 438 x 138 (3U) | |
| Net weight (kg) UPS | 13.50 kg | 16 kg |
| Net weight (kg) battery bank | 55 kg | 63 kg |
| ENVIRONMENTAL CONDITIONS | ||
| Humidity | <95% non-condensing | |
| Operating temperature | 0–40°C (battery life is reduced at temp. >25°C) | |
| Operating altitude | <1000 m | |
| Noise level | <55 dB @ 1 m | |
| SOFTWARE MANAGEMENT | ||
| Smart RS-232 & USB | Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and Mac | |
| Optional SNMP | Power management via SNMP manager and web browser. | |
MODELS
Capacity*
6K RACK
6000VA / 6000W
10K RACK
10000VA / 10000W
INPUT
Line loss
110–300 VAC @ (0–60%) load / 140–300 VAC @ (60–80%) load / 176–300 VAC @ (80–100%) load
Line recovery - low
Low line-loss voltage + 10 V
Line recovery - high
High line-loss voltage - 10 V
Frequency range
Programmable 46 Hz–54 Hz @ 50 Hz / 56 Hz–64 Hz @ 60 Hz
Phase
Single-phase with earth (phase + neutral)
Power factor
≧ 0.99 at nominal voltage and 100% load
THDi
< 4% at 100% load, <6% at 50% load
OUTPUT
Low-voltage transfer
Programmable 208/220/230/240 VAC
AC voltage regulation (Battery mode)
± 1%
Frequency range (Synchronized range)
Programmable 46 Hz–54 Hz @ 50 Hz / 56 Hz–64 Hz @ 60 Hz
Frequency range (Battery mode)
Programmable 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest factor
3:1
Harmonic distortion
≦ 1% @ 100% linear loads; ≦ 4% @ 100% non-linear loads
Mains ↔ Battery
0 ms
Inverter ↔ Bypass
0 ms
Inverter ↔ ECO
< 10 ms
Waveform (Battery mode)
Pure sine wave
EFFICIENCY
AC mode
> 94%
ECO mode
> 94%
BATTERY
Battery type
6K RACK
12 V / 7 AH
10K RACK
12 V / 9 AH
Quantity
6K RACK
20
10K RACK
20
Typical recharge time
6K RACK
7 hours to recharge 90% capacity
10K RACK
9 hours to recharge 90% capacity
Charging current
1 A ± 10% (max.)
Charging voltage
(Number of batteries*13.65 V) ± 1%
INDICATORS
LCD display
UPS status, load level, battery level, input/output voltage, discharge time, and fault conditions.
ALARMS
Battery mode
Beep every 4 seconds
Low battery
Beep every second
Overload
Beep twice every second
Fault
Continuous beep
PHYSICAL DATA
UPS dimensions D x W x H (mm)
600 x 438 x 88 (2U)
Battery bank dimensions D x W x H (mm)
600 x 438 x 138 (3U)
Net weight (kg) UPS
6K RACK
13.50 kg
10K RACK
16 kg
Net weight (kg) battery bank
6K RACK
55 kg
10K RACK
63 kg
ENVIRONMENTAL CONDITIONS
Humidity
<95% non-condensing
Operating temperature
0–40°C (battery life is reduced at temp. >25°C)
Operating altitude
<1000 m
Noise level
< 55 dB @ 1 m
SOFTWARE MANAGEMENT
Smart RS-232 & USB
Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and Mac
Optional SNMP
Power management via SNMP manager and web browser.
Documentation
Documents automatically generated in the page language.