THREE-PHASE UPS LA-ON3113-LCD-V.10
Three-Phase UPS LA-ON3113-LCD-V10 with Online technology and configurable 3:3 and 3:1 design, with true double conversion, DSP technology, output power factor 1 and color touchscreen LCD display, also integrating parallel operation of up to 4 units, adjustable charging, maintenance bypass and advanced management to ensure continuous, stable and safe power supply in critical applications.

✓True double conversion Online UPS
✓Configurable 3:3 - 3:1
✓DSP technology ensures high performance
✓Output power factor 1
✓Silicon carbide diodes to improve system efficiency
✓Dual input voltage system
✓Adjustable charging current
✓Supports up to 4 units in parallel with common battery
✓5" colour touchscreen LCD display
✓High overload capacity
✓Very powerful charger to shorten recharge time
✓Multiple communication ports SNMP (Optional) + USB + RS-232
✓Adjustable battery design
✓Maintenance bypass available
Description
Advanced power supply system with DSP technology, offering high performance as well as reliable electrical protection for your equipment, suitable for industrial applications with three-phase input and output.
UPS LA-ON3113-V.10 Series OnLine Configurable
| Model | LA-ON3113-10K-LCD-V10 | LA-ON3113-20K-LCD-V10 |
|---|---|---|
| Capacity* | 10KVA / 10KW | 20KVA / 20KW |
| INPUT | ||
| Low line loss | 110 VAC (Ph-N) ±3 % at 50% load; 176 VAC (Ph-N) ±3 % at 100% load | |
| Low line return | Low line loss voltage + 10V | |
| High line loss | 300 VAC (L-N) ±3 % at 50% load; 276 VAC (L-N) ±3 % at 100% load | |
| High line return | High line loss voltage - 10V | |
| Frequency range | 46Hz ~ 54Hz @ 50Hz system; 56Hz ~ 64Hz @ 60Hz system | |
| Phase | Three-phase with neutral | |
| Power factor | ≧ 0.99 at 100% load | |
| OUTPUT | ||
| Phase | Three-phase with neutral | |
| Output voltage | 360/380/400/415VAC (Ph-Ph) / 208*/220/230/240VAC (Ph-N) | |
| AC voltage regulation | ± 1% | |
| Frequency range (Synchronized range) | 46Hz ~ 54Hz @ 50Hz system; 56Hz ~ 64Hz @ 60Hz system | |
| Frequency range (Batt. Mode) | 50 Hz ± 0.1Hz or 60Hz ± 0.1 Hz | |
| Overload AC Mode | 100%~110%: 60min; 110%~125%: 10min; 125%~150%: 1min; >150%: immediately | |
| Overload Battery Mode | 100%~110%: 60min; 110%~125%: 10min; 125%~150%: 1min; >150%: immediately | |
| Current crest ratio | 3:1 maximum | |
| Harmonic distortion | ≦ 2% @ 100% linear load; ≦5 % @ 100% non-linear load | |
| Line/Battery | 0 ms | |
| Inverter/Bypass | 0 ms (When phase lock fails, an interruption of <4 ms occurs from inverter to bypass) | |
| Inverter/ECO | <10 ms | |
| EFFICIENCY | ||
| AC Mode | 95.5% | |
| ECO mode | 98.5% | |
| Battery Mode | 94.5% | |
| BATTERY | ||
| Standard model - Type | 12 V / Ah9 | 12 V / Ah9 |
| Standard model - Numbers | (10+10) pieces | (20+20) pieces |
| Standard model - Recharge time | 9 hours recover 90% of capacity | |
| Standard model - Charging current (max.) | 1.0 A ± 10% (recommended) | 1.0~12.0A (adjustable) |
| Standard model - Charging voltage | +/-136.5 VDC ± 1% | +/-218VDC ± 1% |
| Long-term model - Type | Depending on applications | |
| Long-term model - Numbers | 20 | 32 ~ 40 (adjustable) |
| Long-term model - Charging current (max.) | 1.0~12.0A ±10% (adjustable) | |
| Long-term model - Charging voltage | +/-136.5 VDC ± 1% | +/-13.65 VDC * N ± 1% (N = 16~20) |
| PHYSICAL | ||
| Standard model - Dimension, D x W x H mm | 626 x 250 x 826 | |
| Standard model - Net weight (kgs) | 126 | 141 |
| Long-term model - Dimension, D x W x H mm | 626 x 250 x 826 | |
| Long-term model - Net weight (kgs) | 30 (Without batteries) | 45 (Without batteries) |
| ENVIRONMENT | ||
| Operating temperature | 0 ~ 40°C (battery life will decrease when above 25°C) | |
| Operating humidity | < 95% and non-condensing | |
| Operating altitude | < 1000m | |
| Acoustic noise level | Less than 58dB at 1 meter | Less than 60dB at 1 meter |
| MANAGEMENT | ||
| Intelligent RS-232 or USB | Compatible with Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and MAC | |
| Optional SNMP | Power management from SNMP manager and web browser | |
MODELS
Capacity*
10K
10KVA / 10KW
20K
20KVA / 20KW
INPUT
Low line loss
110 VAC (Ph-N) ±3 % at 50% load; 176 VAC (Ph-N) ±3 % at 100% load
Low line return
Low line loss voltage + 10V
High line loss
300 VAC (L-N) ±3 % at 50% load; 276 VAC (L-N) ±3 % at 100% load
High line return
High line loss voltage - 10V
Frequency range
46Hz ~ 54Hz @ 50Hz system; 56Hz ~ 64Hz @ 60Hz system
Phase
Three-phase with neutral
Power factor
≧ 0.99 at 100% load
OUTPUT
Phase
Three-phase with neutral
Output voltage
360/380/400/415VAC (Ph-Ph) / 208*/220/230/240VAC (Ph-N)
AC voltage regulation
± 1%
Frequency range (Synchronized range)
46Hz ~ 54Hz @ 50Hz system; 56Hz ~ 64Hz @ 60Hz system
Frequency range (Batt. Mode)
50 Hz ± 0.1Hz or 60Hz ± 0.1 Hz
Overload AC Mode
100%~110%: 60min; 110%~125%: 10min; 125%~150%: 1min; >150%: immediately
Overload Battery Mode
100%~110%: 60min; 110%~125%: 10min; 125%~150%: 1min; >150%: immediately
Current crest ratio
3:1 maximum
Harmonic Distortion
≦ 2% @ 100% linear load; ≦5 % @ 100% non-linear load
Line/Battery
0 ms
Inverter/Bypass
0 ms (When phase lock fails, an interruption of <4 ms occurs from inverter to bypass)
Inverter/ECO
<10 ms
EFFICIENCY
AC mode
95.5%
ECO Mode
98.5%
Battery mode
94.5%
BATTERY
Standard model - Type
10K
12 V / Ah9
20K
12 V / Ah9
Standard model - Numbers
10K
(10+10) pieces
20K
(20+20) pieces
Standard model - Recharge time
9 hours recover 90% of capacity
Standard model - Charging current (max.)
10K
1.0 A ± 10% (recommended)
20K
1.0~12.0A (adjustable)
Standard model - Charging voltage
10K
+/-136.5 VDC ± 1%
20K
+/-218VDC ± 1%
Long-term model - Type
Depending on applications
Long-term model - Numbers
10K
20
20K
32 ~ 40 (adjustable)
Long-term model - Charging current (max.)
1.0~12.0A ±10% (adjustable)
Long-term model - Charging voltage
10K
+/-136.5 VDC ± 1%
20K
+/-13.65 VDC * N ± 1% (N = 16~20)
PHYSICAL
Standard model - Dimension, D x W x H mm
626 x 250 x 826
Standard model - Net weight (kgs)
10K
126
20K
141
Long-term model - Dimension, D x W x H mm
626 x 250 x 826
Long-term model - Net weight (kgs)
10K
30 (Without batteries)
20K
45 (Without batteries)
ENVIRONMENT
Operating temperature
0 ~ 40°C (battery life will decrease when above 25°C)
Operating humidity
< 95% and non-condensing
Operating altitude
< 1000m
Acoustic noise level
10K
Less than 58dB at 1 meter
20K
Less than 60dB at 1 meter
MANAGEMENT
Intelligent RS-232 or USB
Compatible with Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and MAC
Optional SNMP
Power management from SNMP manager and web browser