THREE-PHASE UPS LA-ON33-V.10

Watch the product videoYouTube

Three-phase UPS LA-ON33-LCD-V10 designed for critical three-phase installations from 10KVA to 30KVA, with true double conversion, DSP technology, output power factor 1 and colour touchscreen LCD display, also offering parallel operation of up to 4 units, high overload capacity, adjustable charging and advanced management to guarantee safe, stable and continuous power supply.



Three-phase UPS LA-ON33-LCD

Categories: , Tags: ,
✓True double conversion online UPS
✓DSP technology ensuring high performance
✓Output power factor 1
✓Silicon carbide diodes to improve system efficiency
✓Dual input voltage system
✓Adjustable charging current
✓Supports up to 4 units in parallel with common battery
✓5" colour touchscreen LCD display
✓High overload capacity
✓Very powerful charger to shorten recharge time
✓Multiple communication ports SNMP (Optional) + USB + RS-232
✓Adjustable battery design
✓Maintenance bypass available
✓Optional programmable relay dry contact card

Description

Advanced power supply system with DSP technology, offering high performance as well as reliable electrical protection for your equipment, suitable for industrial applications with three-phase input and output.

UPS LA-ON-33-V.10 Series On-Line

Model LA-ON33-10K-LCD-V10 LA-ON33-20K-LCD-V10 LA-ON33-30K-LCD-V10
Capacity* 10,000 VA / 10,000 W 20,000 VA / 20,000 W 30,000 VA / 30,000 W
Parallel compatibility Up to 4 units in parallel
INPUT
Nominal voltage 3 X 400 VAC (3F+N)
Voltage range 190-520 VAC (3 Phase) @ 50% Load / 305-478 VAC (3 Phase) @ 100% Load
Frequency range 46Hz ~ 54 Hz or 56Hz ~ 64Hz
Power factor ≧ 0.99 at 100% load
OUTPUT
Output voltage 3 X 360*/380/400/415 VAC (3F+N)
AC voltage regulation (Battery mode) ±1%
Frequency range (Synchronised range) 46Hz ~ 54 Hz or 56Hz ~ 64Hz
Frequency range (Battery mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Harmonic distortion ≦ 2 % THD linear loads / ≦ 5 % THD non-linear loads
Overload AC mode 100%~110%: for 60min; 110%~125%: 10min; >150% : 1sec
Overload battery mode 100%~110%: for 60min; 110%~125%: 10min; >150% : 1sec
Crest current value 3:1 max
Transfer time Mains - Battery 0 ms
Inverter - Bypass 0 ms
Current crest ratio 3:1 (max)
Waveform (Battery mode) Pure sine wave
EFFICIENCY
AC mode 96.0%
ECO mode 98.5%
Battery mode 95.0%
BATTERY
Battery type 12 V / 9AH 12 V / 9AH 12 V / 7 AH
Number (10 + 10) units (16 + 16) units (16 +16) units X 2 series
Recharge time 9 hours recharge 90% capacity
Charging current (max) 1A ~ 12A (Adjustable)
Charging voltage ±136.5 VDC ± 10% ±218 VDC ± 10%
INDICATORS
5" colour touchscreen LCD display UPS status, load level, battery level, input/output voltage, discharge time and faults
ALARM
Battery mode Sound every 4 seconds
Low battery Sound every second
Overload Sounds twice every second
Fault Continuous sound
PHYSICAL CHARACTERISTICS
Standard model 626 X 250 X 750 (mm) 815 X 300 X 1000 (mm)
Net weight (kgs) 124 Kg 139 Kg 225 Kg
ENVIRONMENTAL CONDITIONS
Operating temperature 0 ~ 40°C (battery life reduced with temp. > 25°C)
Relative humidity <95 % non-condensing
Noise level < 55dBA at 1 metre < 58dBA at 1 metre < 65dBA at 1 metre
MANAGEMENT
Smart RS-232 OR USB Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC
Optional SNMP Power management via SNMP manager and web browser

MODELS
Capacity*
10K
10,000 VA / 10,000 W
20K
20,000 VA / 20,000 W
30K
30,000 VA / 30,000 W
Parallel compatibility
Up to 4 units in parallel
INPUT
Nominal voltage
3 X 400 VAC (3F+N)
Voltage range
190-520 VAC (3 Phase) @ 50% Load / 305-478 VAC (3 Phase) @ 100% Load
Frequency range
46Hz ~ 54 Hz or 56Hz ~ 64Hz
Power factor
≧ 0.99 at 100% load
OUTPUT
Output voltage
3 X 360*/380/400/415 VAC (3F+N)
AC voltage regulation (Battery mode)
±1%
Frequency range (Synchronised range)
46Hz ~ 54 Hz or 56Hz ~ 64Hz
Frequency range (Battery mode)
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Harmonic distortion
≦ 2 % THD linear loads / ≦ 5 % THD non-linear loads
Overload AC mode
100%~110%: for 60min; 110%~125%: 10min; >150% : 1sec
Overload battery mode
100%~110%: for 60min; 110%~125%: 10min; >150% : 1sec
Crest current value
3:1 max
Transfer time Mains - Battery
0 ms
Inverter - Bypass
0 ms
Current crest ratio
3:1 (max)
Waveform (Battery Mode)
Pure sine wave
EFFICIENCY
AC mode
96.0%
ECO mode
98.5%
Battery mode
95.0%
BATTERY
Battery type
10K
12 V / 9AH
20K
12 V / 9AH
30K
12 V / 7 AH
Number
10K
(10 + 10) units
20K
(16 + 16) units
30K
(16 +16) units X 2 series
Recharge time
9 hours recharge 90% capacity
Charging current (max)
1A ~ 12A (Adjustable)
Charging voltage
10K
±136.5 VDC ± 10%
20K / 30K
±218 VDC ± 10%
INDICATORS
5" colour touchscreen LCD display
UPS status, load level, battery level, input/output voltage, discharge time and faults
ALARM
Battery mode
Sound every 4 seconds
Low battery
Sound every second
Overload
Sounds twice every second
Fault
Continuous sound
PHYSICAL CHARACTERISTICS
Standard model
10K
626 X 250 X 750 (mm)
20K / 30K
815 X 300 X 1000 (mm)
Net weight (kgs)
10K
124 Kg
20K
139 Kg
30K
225 Kg
ENVIRONMENTAL CONDITIONS
Operating temperature
0 ~ 40°C (battery life reduced with temp. > 25°C)
Relative humidity
<95 % non-condensing
Noise level
10K
< 55dBA at 1 metre
20K
< 58dBA at 1 metre
30K
< 65dBA at 1 metre
MANAGEMENT
Smart RS-232 OR USB
Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC
Optional SNMP
Power management via SNMP manager and web browser

Documentation

PDF
Datasheet
PDF
EU Declaration of Conformity
PDF
RoHS declaration
PDF
Certificate of origin
PDF
User manual

Documents automatically generated in the page language.