ONLINE UPS LA-ON-LCD-V.10

Watch the product videoYouTube

LA-ON-LCD-V1.0 true double conversion online UPS designed to provide maximum electrical continuity and high output quality in professional environments, incorporating power factor 1, wide input voltage range, low harmonic distortion, ECO mode, advanced load control, and USB, RS232, and SNMP communications for efficient and secure critical power management.



Online UPS LA-ON-LCD icons

Categories: , Tag:
✓True Online Double Conversion UPS
✓Microprocessor control for optimized reliability
✓Output power factor 1
✓Input power factor correction
✓Wide input voltage range (110V - 300V)
✓Optional ECO mode operation for energy saving
✓Emergency Power Off (EPO) function
✓Built-in surge protection and MOV surge immunity for full-time equipment protection
✓Power factor charger up to 1000W with very low ripple current when charging the battery
✓Low THDi input to reduce power system contamination
✓Adjustable charging current via LCD panel
✓Battery charger design for optimized battery performance
✓Generator compatible
LA-ON-LCD-V.10 Series Online UPS

Model LA-ON-1K-LCD-V.10 LA-ON-2K-LCD-V.10 LA-ON-3K-LCD-V.10
Capacity* 1000VA / 1000W 2000VA / 2000W 3000VA / 3000W
INPUT
Low mains voltage transfer 160VAC/140VAC/120VAC/110VAC ±5% or 80VAC/70VAC/60VAC/55VAC ±5% (based on load percentage 100% - 80% / 80% - 70% / 70 - 60% / 60% - 0)
Low mains voltage return 175VAC/155VAC/135VAC/125VAC ±5% or 87VAC/77VAC/67VAC/62VAC ±5%
High mains voltage transfer 300 VAC ±5% or 150 VAC ±5%
High mains voltage return 290 VAC ±5% or 145 VAC ±5%
Frequency range 40Hz ~ 70Hz
Phase Single phase with ground (phase + neutral)
Power factor ≧ 0.99 @ rated voltage and 100% load
THDi ≦5% @ 205-245 VAC or 100 ~ 130 VAC THDU < 1.6% @ linear load and charged battery
OUTPUT
Output voltage 200/208/220/230/240 VAC or 100/110/115/120/127 VAC
AC voltage regulation (Battery mode) 1%
Frequency range (Synchronized range) 47~53Hz or 57~63Hz
Frequency range (Battery mode) 50 Hz ±0.1 Hz or 60Hz ±0.1 Hz
Crest factor ratio 3:1
Harmonic distortion ≦2%THD (Linear load); ≦4%THD (Non-linear load)
Transfer time AC mode to Battery mode Zero
Inverter to Bypass 4 ms
Waveform (Battery mode) Pure sine wave
EFFICIENCY
AC Mode 89% @ charged battery 91% @ charged battery 91% @ charged battery
ECO Mode 96% @ charged battery
Battery Mode ≥ 88% ≥ 90% ≥ 90%
BATTERY
Battery type 12V / 7AH 12V / 7AH 12V / 9AH
Quantity 3 6 6
Typical recharge time 3 hours to recover 95% capacity at 2A charging current
Charging current 100/110/115/120/127 VAC models: default 2A, max. adjustable to 8A. 200/208/220/230/240 VAC models: default 2A, max. adjustable 12A Default: 2A, Max: adjustable 8A
Charging voltage 41.0 VDC ±1% 82.1 VDC ±1%
CONNECTIONS
Current outputs 4xIEC C13 8xIEC C13 8xIEC C13 + 1xIEC C19
Communication ports 1xUSB + 1xRS232 + 1xSNMP smart slot
PHYSICAL DATA
Dimensions D x W x H (mm) 397 x 145 x 220 421 x 190 x 318
Net weight (Kg) with batteries 12.90 22.80 27.00
Net weight (Kg) without batteries 6.6 9.9 12.3
WORKING ENVIRONMENT
Humidity 20-95% RH @ 0-40 C (non-condensing)
Noise level < 50dBA @ 1 meter (with fan speed control)
SOFTWARE MANAGEMENT
Smart RS-232 & USB Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and Mac
Optional SNMP Power management from SNMP manager and web browser

MODELS
Capacity*
1K
1000VA / 1000W
2K
2000VA / 2000W
3K
3000VA / 3000W
INPUT
Low mains voltage transfer
160VAC/140VAC/120VAC/110VAC ±5% or 80VAC/70VAC/60VAC/55VAC ±5%
Low mains voltage return
175VAC/155VAC/135VAC/125VAC ±5% or 87VAC/77VAC/67VAC/62VAC ±5%
High mains voltage transfer
300 VAC ±5% or 150 VAC ±5%
High mains voltage return
290 VAC ±5% or 145 VAC ±5%
Frequency range
40Hz ~ 70Hz
Phase
Single phase with ground (phase + neutral)
Power factor
≧ 0.99 @ rated voltage and 100% load
THDi
≦5% @ 205-245 VAC or 100 ~ 130 VAC THDU < 1.6% @ linear load and charged battery
OUTPUT
Output voltage
200/208/220/230/240 VAC or 100/110/115/120/127 VAC
AC voltage regulation (Battery mode)
1%
Frequency range (Synchronized range)
47~53Hz or 57~63Hz
Frequency range (Battery mode)
50 Hz ±0.1 Hz or 60Hz ±0.1 Hz
Crest factor ratio
3:1
Harmonic distortion
≦2%THD (Linear load); ≦4%THD (Non-linear load)
Transfer time AC mode to Battery mode
Zero
Inverter to Bypass
4 ms
Waveform (Battery mode)
Pure sine wave
EFFICIENCY
AC Mode
1K
89% @ charged battery
2K
91% @ charged battery
3K
91% @ charged battery
ECO Mode
96% @ charged battery
Battery Mode
1K
≥ 88%
2K
≥ 90%
3K
≥ 90%
BATTERY
Battery type
1K
12V / 7AH
2K
12V / 7AH
3K
12V / 9AH
Quantity
1K
3
2K
6
3K
6
Typical recharge time
3 hours to recover 95% capacity at 2A charging current
Charging current
1K
100/110/115/120/127 VAC models: default 2A, max. adjustable to 8A. 200/208/220/230/240 VAC models: default 2A, max. adjustable 12A
2K / 3K
Default: 2A, Max: adjustable 8A
Charging voltage
1K
41.0 VDC ±1%
2K / 3K
82.1 VDC ±1%
CONNECTIONS
Current outputs
1K
4xIEC C13
2K
8xIEC C13
3K
8xIEC C13 + 1xIEC C19
Communication ports
1xUSB + 1xRS232 + 1xSNMP smart slot
PHYSICAL DATA
Dimensions D x W x H (mm)
1K
397 x 145 x 220
2K / 3K
421 x 190 x 318
Net weight (Kg) with batteries
1K
12,90
2K
22,80
3K
27,00
Net weight (Kg) without batteries
1K
6.6
2K
9.9
3K
12.3
WORKING ENVIRONMENT
Humidity
20-95% RH @ 0-40 C (non-condensing)
Noise level
< 50dBA @ 1 meter (with fan speed control)
SOFTWARE MANAGEMENT
Smart RS-232 & USB
Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and Mac
Optional SNMP
Power management from SNMP manager and web browser

Documentation

PDF
Datasheet
PDF
EU Declaration of Conformity
PDF
RoHS declaration
PDF
Certificate of origin
PDF
User manual

Documents automatically generated in the page language.