AS400 COMMUNICATION CARD

Watch the product videoYouTube

AS400 communication card designed to provide remote monitoring via contacts in equipment with intelligent slot, available in version with DB9 external connector or 9-pin connector, maintaining in both cases the same functionality for signaling critical UPS states and the same jumper configuration for adaptation to different integration environments.

  • Multiple UPS monitoring
  • Remote security protection
  • Audible alarm notifications
  • Simple one-click firmware update
✓AS400 communication card for Lapara UPS and compatible equipment with intelligent slot
✓Available in version with DB9 external connector or 9-pin connector
✓Remote monitoring of UPS status via signals through the communication connector
✓Signal state selection open or closed via jumper configuration
✓Signal assignment for UPS fault, audible alarm, active bypass and low battery
✓Dedicated ON/OFF input via connector pin 4
✓Simple integration in environments requiring contact signaling
AS400 communication card for Lapara UPS

Parameter DB9 version 9-pin connector version
Product AS400 communication card for Lapara UPS AS400 communication card for Lapara UPS
Compatibility Lapara UPS and compatible with intelligent slot Lapara UPS and compatible with intelligent slot
Main function Remote monitoring of UPS status via signals Remote monitoring of UPS status via signals
Signal configuration Open or closed state selection via jumpers Open or closed state selection via jumpers
External connector DB9 9-pin connector
PIN ASSIGNMENT
Pin 1 UPS fault
Pin 2 UPS audible alarm
Pin 3 GND
Pin 4 ON/OFF input
Pin 5 Relays
Pin 6 Active bypass
Pin 7 Low battery
Pin 9 Not used
JUMPER DESCRIPTION
JP1 UPS alarm → Pin 2
JP2 UPS on → Pin 5
JP3 Bypass → Pin 6
JP4 Low battery → Pin 7
JP5 Not used → Pin 9
JP6 UPS fault → Pin 1

GENERAL
Product
DB9
AS400 communication card for Lapara UPS
9-PIN
AS400 communication card for Lapara UPS
Compatibility
Lapara UPS and compatible with intelligent slot
Main function
Remote monitoring of UPS status via signals
Signal configuration
Open or closed state selection via jumpers
External connector
DB9
DB9
9-PIN
9-pin connector
PIN ASSIGNMENT
Pin 1
UPS fault
Pin 2
UPS audible alarm
Pin 3
GND
Pin 4
ON/OFF input
Pin 5
Relays
Pin 6
Active bypass
Pin 7
Low battery
Pin 9
Not used
JUMPER DESCRIPTION
JP1
UPS alarm → Pin 2
JP2
UPS on → Pin 5
JP3
Bypass → Pin 6
JP4
Low battery → Pin 7
JP5
Not used → Pin 9
JP6
UPS fault → Pin 1

Documentation

PDF
Datasheet
PDF
EU Declaration of Conformity
PDF
RoHS declaration
PDF
Certificate of origin

Documents automatically generated in the page language.