MAINTENANCE BYPASS FOR UPS LA-PDU-SM-R-IEC
Maintenance bypass for UPS designed for rack installations with UPS up to 3000 VA, allowing manual transfer of the load to the mains without interrupting supply, thus facilitating UPS maintenance or replacement tasks. Its Master/Slave design adds an energy-saving function within a compact and easy-to-integrate 19″ rack format.
✓19" rack maintenance bypass for UPS and large regulators
✓Allows manual transfer of the load to the mains without interrupting supply
✓Provides continuous power to connected equipment during UPS maintenance
✓Master/Slave design for energy saving
✓Automatic disconnection of Slave outputs when Master output consumption is less than 20W (±5W)
✓Easy operation via rotary switch
✓Plug & Play connectivity for both input and output
✓Suitable for all UPS up to 3000 VA
✓5 IEC C13 outlets and 1 IEC C19 outlet in compact rack format
19" Rack Maintenance Bypass LA-PDU-SM-R-IEC
| Parameter | LA-PDU-SM-R-IEC |
|---|---|
| Product | Maintenance Bypass Switch / Maintenance Bypass |
| Model | LA-PDU-SM-R-IEC |
| Model Code | 19” MBS |
| Application | External distribution unit for UPS |
| ELECTRICAL CHARACTERISTICS | |
| Rated Current | 16A |
| Rated Voltage | 208 / 220 / 230 / 240 VAC |
| Energy Saving | Yes. If Master output consumption is less than 20W (±5W), Slave outputs are disconnected |
| LED INDICATORS | |
| Power LED | Green illumination |
| Master/Slave Function LED | Green illumination |
| CONNECTIONS | |
| Main Power | 1 x IEC C20 (16A) |
| Input from UPS | 1 x IEC C20 (16A) |
| Output to UPS | 1 x IEC C19 (16A) |
| Master Output | 1 x IEC C19 (16A) + 1 x IEC C13 (10A) |
| Slave Output | 4 x IEC C13 (10A) |
| PHYSICAL DATA | |
| Dimensions | 438 x 80 x 50 mm |
| Color | Black |
| Weight | 1.5 kg |
| Format | 19" Rack |
| WORKING ENVIRONMENT | |
| Temperature | 0°C – 40°C |
| Humidity | 20% - 90% RH (non-condensing) |
| CONTENTS AND LOGISTICS | |
| Package Contents | LA-PDU-SM-R-IEC Maintenance Bypass, input cable |
GENERAL
Product
Maintenance Bypass Switch / Maintenance Bypass
Model
LA-PDU-SM-R-IEC
Model Code
19” MBS
Application
External distribution unit for UPS
ELECTRICAL CHARACTERISTICS
Rated Current
16A
Rated Voltage
208 / 220 / 230 / 240 VAC
Energy Saving
Yes. If Master output consumption is less than 20W (±5W), Slave outputs are disconnected
LED INDICATORS
Power LED
Green illumination
Master/Slave Function LED
Green illumination
CONNECTIONS
Main Power
1 x IEC C20 (16A)
Input from UPS
1 x IEC C20 (16A)
Output to UPS
1 x IEC C19 (16A)
Master Output
1 x IEC C19 (16A) + 1 x IEC C13 (10A)
Slave Output
4 x IEC C13 (10A)
PHYSICAL DATA
Dimensions
438 x 80 x 50 mm
Color
Black
Weight
1.5 kg
Format
19" Rack
WORKING ENVIRONMENT
Temperature
0°C – 40°C
Humidity
20% - 90% RH (non-condensing)
CONTENTS AND LOGISTICS
Package Contents
LA-PDU-SM-R-IEC Maintenance Bypass, input cable